SimpleComTools COM1000 Guía de usuario

Busca en linea o descarga Guía de usuario para Redes SimpleComTools COM1000. SimpleComTools COM1000 User guide [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 115
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Raven CDMA/1x

Raven CDMA/1x User Guide AirLink Communications, Inc.version 2.23May 2006

Pagina 2 - Limitation of Liability

Introduction to Raven CDMA4 Raven CDMA User Guide for Verizon, version 2.23Common Uses for the Raven The Raven’s rugged construction and cellular conn

Pagina 3 - Contents

94 Raven CDMA User Guide for Verizon, version 2.23STATUS current ::= { common 1 }otaProgrammingEnable OBJECT-TYPESYNTAX INTEGER {disabled(0),enab

Pagina 4

Raven CDMA User Guide for Verizon, version 2.23 95requestPAP OBJECT-TYPESYNTAX INTEGER {no(0),yes(1) }MAX-ACCESS read-onlySTATUS current ::= {

Pagina 5

96 Raven CDMA User Guide for Verizon, version 2.23SYNTAX INTEGER {none(0),hardware(2),software(4) }MAX-ACCESS read-onlySTATUS current ::= { comm

Pagina 6

Raven CDMA User Guide for Verizon, version 2.23 97SYNTAX INTEGER(-125..-50)MAX-ACCESS read-onlySTATUS current ::= { status 4 }serialSent OBJECT

Pagina 7 - Introduction to

98 Raven CDMA User Guide for Verizon, version 2.23 fixObtained OBJECT-TYPESYNTAX INTEGER {no(0),yes(1) }MAX-ACCESS read-onlySTATUS current ::

Pagina 8 - CDMA Overview

Raven CDMA User Guide for Verizon, version 2.23 99

Pagina 9 - Equipment

Raven CDMA User Guide for Verizon, version 2.23 100Troubleshooting Frequently Asked Questions (FAQ) and SolutionsMany of these questions and solutions

Pagina 10 - Common Uses for the Raven

Raven CDMA User Guide for Verizon, version 2.23 101AirLink modems optimally have an RSSI value of -60 to -95.What is the Proper RF Coverage for my Rav

Pagina 11 - Introduction to Raven CDMA

102 Raven CDMA User Guide for Verizon, version 2.23The short dipole antenna (also known as a “rubber duck”) is a good desktop, porta-ble antenna for u

Pagina 12 - Activation of the Raven

Raven CDMA User Guide for Verizon, version 2.23 103the modem. You can contact AirLink Support for a Guide on how to use your Air-Link modem with a po

Pagina 13

Raven CDMA User Guide for Verizon, version 2.23 5Introduction to Raven CDMAFIGURE 5. Backup connection to the Internet

Pagina 14 - Raven Indicator Lights

104 Raven CDMA User Guide for Verizon, version 2.23Public Mode (*HOSTPRIVMODE=0) :The IP address assigned by Verizon is passed on to the devices conne

Pagina 15 - Activation of the Raven CDMA

Raven CDMA User Guide for Verizon, version 2.23 105*HOSTPRIVMODE=1 - Private Mode turned on. *HOSTPRIVIP=[IP address] - IP address assigned to compute

Pagina 16 - Utilities for the Raven

106 Raven CDMA User Guide for Verizon, version 2.23“The COM1000 provides you with a single device that can be seamlessly inte-grated into LAN, WAN, an

Pagina 17 - Wireless ACE 3G

Raven CDMA User Guide for Verizon, version 2.23 107AT CommandsYou can use AT commands to manually trigger an Over-the-Air PRL update.FIGURE 3. Wirele

Pagina 18 - FIGURE 2. AceNet

108 Raven CDMA User Guide for Verizon, version 2.23Modem has not registered: This can be a transitory state. Wait 30 to 60 seconds and attempt the

Pagina 19 - FIGURE 3. AceView

Raven CDMA User Guide for Verizon, version 2.23 109Support web site The Airlink web site is updated frequently with Setup Wizards, Utilities, FAQs, an

Pagina 20 - Modem Doctor

Raven CDMA User Guide for Verizon, version 2.23 6CHAPTER 2 Activation of the Raven CDMAYour Raven needs specific parameters before it can operate on t

Pagina 21 - IP Manager

Raven CDMA User Guide for Verizon, version 2.23 7Activation of the Raven CDMATo run the Setup Wizard, you will need the Microsoft .NET framework and M

Pagina 22 - Dynamic Name Resolution

Activation of the Raven CDMA8 Raven CDMA User Guide for Verizon, version 2.23Activating the Raven using AT Commands An alternate method to configure a

Pagina 23

Raven CDMA User Guide for Verizon, version 2.23 9Activation of the Raven CDMAPwr - Indicates the power adapter is connected and there is power getting

Pagina 24 - • Cannot contain spaces

Raven CDMA User Guide for Verizon, version 2.23 10CHAPTER 3 Utilities for the RavenAirLink offers a suite of utilities to optimize your Raven’s perfor

Pagina 25 - Configuring DNS

Raven CDMA User Guide for Verizon, version 2.23 11Utilities for the RavenAirLink Configuration Executive (ACE) The AirLink Configuration Executive pro

Pagina 26 - PPP-Peer

Utilities for the Raven12 Raven CDMA User Guide for Verizon, version 2.23AceNetWith AceNet you can monitor several AirLink modems at the same time. T

Pagina 27 - Keepalive

Raven CDMA User Guide for Verizon, version 2.23 13Utilities for the RavenFIGURE 3. AceViewYou can connect to your Raven locally or remotely using a k

Pagina 28 - Data usage using Keepalive

ii Raven CDMA User Guide for Verizon, version 2.23Information in this document is subject to change without notice©Copyright AirLink Communications, I

Pagina 29 - Host Modes

Utilities for the Raven14 Raven CDMA User Guide for Verizon, version 2.23Modem DoctorModem Doctor is a troubleshooting utility. This utility will all

Pagina 30

Raven CDMA User Guide for Verizon, version 2.23 15CHAPTER 4 IP Manager IP Manager translates a dynamic IP address to a fully qualified domain name so

Pagina 31 - PassThru Mode

IP Manager16 Raven CDMA User Guide for Verizon, version 2.23Fully Qualified Domain Name A fully qualified domain name (FQDN) generally has several par

Pagina 32 - Slip Mode

Raven CDMA User Guide for Verizon, version 2.23 17IP ManagerIf the Raven is configured for Dynamic IP, when the Raven first connects to the Internet,

Pagina 33 - UDP Pad Mode

IP Manager18 Raven CDMA User Guide for Verizon, version 2.23FIGURE 1. Wireless ACE: Dynamic IP (IP Manager configuration) 1. Modem name: The name you

Pagina 34 - Reliable UDP

Raven CDMA User Guide for Verizon, version 2.23 19IP ManagerDNS: Using Names Instead of IP addresses A domain name is a name of a server or device on

Pagina 35 - TCP PAD Mode

IP Manager20 Raven CDMA User Guide for Verizon, version 2.23*DNSUSER - Set this, if desired, to an additional DNS server to query first before the pri

Pagina 36 - Hybrid Modes

Raven CDMA User Guide for Verizon, version 2.23 21CHAPTER 5 KeepaliveIt is not uncommon for your Raven to be disconnected from Verizon after an extend

Pagina 37 - Hybrid Mode Settings

Keepalive22 Raven CDMA User Guide for Verizon, version 2.23To set the Keepalive using Wireless ACE, select Other from the menu on the left.FIGURE 1.

Pagina 38 - Configuration

Raven CDMA User Guide for Verizon, version 2.23 23CHAPTER 6 Host ModesThe Raven plays the part of a host when its serial port is connected to a comput

Pagina 39 - Remote Terminal Unit (RTU)

Raven CDMA User Guide for Verizon, version 2.23 iiiContents CHAPTER 1 Introduction to Raven CDMA . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 40 - Raven Modbus on UDP

Host Modes24 Raven CDMA User Guide for Verizon, version 2.23in the AT Command listing, page 66) to the desired mode. If this setting is non-zero, the

Pagina 41 - Modbus on UDP

Raven CDMA User Guide for Verizon, version 2.23 25Host ModesFor V=0 (Terse mode), a numeric result code is output with a single trailing <CR> (n

Pagina 42 - Modbus/BSAP Configuration

Host Modes26 Raven CDMA User Guide for Verizon, version 2.23PPP ModeIn PPP mode, the Raven acts as a PPP server, providing an IP address, and DNS serv

Pagina 43

Raven CDMA User Guide for Verizon, version 2.23 27Host ModesSLIP does not negotiate the IP with the host, so before making a SLIP connection, the host

Pagina 44 - Dynamic IPs

Host Modes28 Raven CDMA User Guide for Verizon, version 2.23When idle, after the time-out has occurred, the Raven is in AT command mode on the serial

Pagina 45 - RTU settings

Raven CDMA User Guide for Verizon, version 2.23 29Host ModesMulticast UDP Multicast UDP results in any data received from the host serial port being s

Pagina 46 - Power Connections

Host Modes30 Raven CDMA User Guide for Verizon, version 2.23The value of S7 (TCP Connection Time-out) specifies the number of seconds to wait, after i

Pagina 47 - Management Protocol

Raven CDMA User Guide for Verizon, version 2.23 31Host Modesas MD5 and MD6 previously accomplished. Setting MD5 and MD6 are still sup-ported, but not

Pagina 48 - Raven SNMP Configuration

Raven CDMA User Guide for Verizon, version 2.23 32CHAPTER 7 Modbus/BSAP Configuration The Raven supports Modbus ASCII, Modbus RTU, BSAP, and can also

Pagina 49 - User Name and Password

Raven CDMA User Guide for Verizon, version 2.23 33Modbus/BSAP ConfigurationTelemetry Telemetry is an automated communications process by which data is

Pagina 50

Contentsiv Raven CDMA User Guide for Verizon, version 2.23CHAPTER 4 IP Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 51 - Trap Destination

Modbus/BSAP Configuration34 Raven CDMA User Guide for Verizon, version 2.23motion control, process control, Distributed Control System and complex net

Pagina 52 - Hardware Installation

Raven CDMA User Guide for Verizon, version 2.23 35Modbus/BSAP ConfigurationConfiguring the Raven at the Polling Host for Modbus on UDP You can use eit

Pagina 53 - Connecting power

Modbus/BSAP Configuration36 Raven CDMA User Guide for Verizon, version 2.23FIGURE 4. Wireless ACE: MD Configuration • ATMD13: Modbus ASCII• ATMD23:

Pagina 54 - Raven CDMA

Raven CDMA User Guide for Verizon, version 2.23 37Modbus/BSAP ConfigurationIn the Host Raven’s configuration, instead of IP address for the Addr List

Pagina 55 - Modem Idle Transmitting

Modbus/BSAP Configuration38 Raven CDMA User Guide for Verizon, version 2.23In Wireless ACE, select Misc in the side menu. Set the destination port (S5

Pagina 56

Raven CDMA User Guide for Verizon, version 2.23 39Modbus/BSAP ConfigurationRTU settings Other parameters may need to be changed, but this is dependent

Pagina 57 - Mounting Kit

Modbus/BSAP Configuration40 Raven CDMA User Guide for Verizon, version 2.23FIGURE 10. RTU to Raven setup FIGURE 11. Power Connections

Pagina 58

Raven CDMA User Guide for Verizon, version 2.23 41CHAPTER 8 Simple Network Management Protocol (SNMP) The Raven can be configured as an SNMP agent and

Pagina 59 - AT Commands

Simple Network Management Protocol (SNMP)42 Raven CDMA User Guide for Verizon, version 2.23Management Information Base (MIB) The management informatio

Pagina 60

Raven CDMA User Guide for Verizon, version 2.23 43Simple Network Management Protocol (SNMP)Security Level *SNMPSECLVL sets the security level and whic

Pagina 61

Raven CDMA User Guide for Verizon, version 2.23 vContentsIDs to IPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 62 - Direct Serial Connection

Simple Network Management Protocol (SNMP)44 Raven CDMA User Guide for Verizon, version 2.23FIGURE 3. Wireless ACE: Changing the Raven Password - Menu

Pagina 63 - AT Command Tables

Raven CDMA User Guide for Verizon, version 2.23 45Simple Network Management Protocol (SNMP)Trap Destination *SNMPTRAPDEST needs to be set with the des

Pagina 64 - Information Commands

Raven CDMA User Guide for Verizon, version 2.23 46CHAPTER 9 Hardware Installation Your AirLink Raven should be mounted in a position that allows easy

Pagina 65

Raven CDMA User Guide for Verizon, version 2.23 47Hardware InstallationConnecting power Your Raven can be used with either DC (available in most auto

Pagina 66 - TABLE 2

Raven CDMA User Guide for Verizon, version 2.23 48APPENDIX 1 Specifications for the Raven CDMAPhysical Characteristics: • Weight: < 1 lb.• Size: 3”

Pagina 67 - Basic Commands

Raven CDMA User Guide for Verizon, version 2.23 49• Humidity: 5%-95% Non-condensing Power Management: • Low power consumption • Dormant connection (id

Pagina 68 - Activation

50 Raven CDMA User Guide for Verizon, version 2.23

Pagina 69

Raven CDMA User Guide for Verizon, version 2.23 51APPENDIX 2 Mounting KitAn optional accessory for your modem is a mounting kit. The bracket is desig

Pagina 70 - Cellular Network

52 Raven CDMA User Guide for Verizon, version 2.23

Pagina 71 - PassThru

Raven CDMA User Guide for Verizon, version 2.23 53APPENDIX 3 AT CommandsJust as with a Hayes compatible analog modem, the Raven parameters can all be

Pagina 72

Contentsvi Raven CDMA User Guide for Verizon, version 2.23 Basic Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 73 - O=Odd E=Even N=None M=Mark

54 Raven CDMA User Guide for Verizon, version 2.23FIGURE 1. Wireless ACE: Using AT Commands To set or commit the changes in the modem, use the Writ

Pagina 74

Raven CDMA User Guide for Verizon, version 2.23 55Start>All Programs>Accessories>Communications>HyperTerminal1. Choose a name for your con

Pagina 75

56 Raven CDMA User Guide for Verizon, version 2.23FIGURE 5. HyperTerminal: AT mode via Telnet 4. Type AT and press Enter. You should get a reply of

Pagina 76

Raven CDMA User Guide for Verizon, version 2.23 572. Select COM1 for the Connect Using. FIGURE 7. HyperTerminal: Comport Setting 3. Change the Bits

Pagina 77

58 Raven CDMA User Guide for Verizon, version 2.23• Some commands have specific parameters while other commands will take whatever your type. • Accep

Pagina 78 - Direct Communication

Raven CDMA User Guide for Verizon, version 2.23 59TABLE 1. Information and StatusCommand Details I[n]n=0 Product name (for example, Raven).n=1 The Ra

Pagina 79

60 Raven CDMA User Guide for Verizon, version 2.23TABLE 2. For most of the commands in the rest of the tables, you can query the current status of the

Pagina 80

Raven CDMA User Guide for Verizon, version 2.23 61 Basic Commands These commands are common to most communication devices using AT Com-mands.TABLE 3.

Pagina 81

62 Raven CDMA User Guide for Verizon, version 2.23ActivationThe preferred method of activating (provisioning) the modem is using the Setup Wizard. Ho

Pagina 82 - Time/Date

Raven CDMA User Guide for Verizon, version 2.23 63TABLE 4. Activation (Provisioning)Command Parameters Details OPRG=n n=0 or 1 Enables/disables over

Pagina 83 - Friends Mode

Raven CDMA User Guide for Verizon, version 2.23 1CHAPTER 1 Introduction to Raven CDMA The Raven's rugged form factor is ideal for industrial and

Pagina 84

64 Raven CDMA User Guide for Verizon, version 2.23Cellular Network The Raven’s cellular network is the connection to CDMA and remote devices or comput

Pagina 85

Raven CDMA User Guide for Verizon, version 2.23 65Local Network and Host Modes The Local network for the Raven is the one to which it is connected phy

Pagina 86

66 Raven CDMA User Guide for Verizon, version 2.23TABLE 6. Local Network and Host Modes Command Parameters Details +++The "+" is ASCII 0x2

Pagina 87

Raven CDMA User Guide for Verizon, version 2.23 67S0=n n=0 | 1 | 2 | 3 This register determines how the Raven responds to an incoming TCP connection r

Pagina 88 - Logging

68 Raven CDMA User Guide for Verizon, version 2.23S51=n n=0 | ASCII codePAD data forwarding character. 0 : No forwarding character. ASCII code of char

Pagina 89 - Modbus Settings

Raven CDMA User Guide for Verizon, version 2.23 69TCPS=n n = minutes (TCPS=0) or seconds (TCPS=1)TCP connection time-out (TCPS) units. Specifies a tim

Pagina 90

70 Raven CDMA User Guide for Verizon, version 2.23*CTSE=n n=0 or 1 Clear To Send Enable This feature asserts CTS when there is a network con-nection.

Pagina 91 - TABLE 16. Modbus Settings

Raven CDMA User Guide for Verizon, version 2.23 71*HOSTPEERIP =d.d.d.d d.d.d.d=local or peer IP of modem Set or query the IP address that can be used

Pagina 92 - SMTP/SMS

72 Raven CDMA User Guide for Verizon, version 2.23Direct CommunicationDirect Communication can be used with the Raven to contact other Internet device

Pagina 93

Raven CDMA User Guide for Verizon, version 2.23 73TelnetIt is possible to communicate with the Raven across a TCP/IP network. Telnet pro-vides a termi

Pagina 94

Introduction to Raven CDMA2 Raven CDMA User Guide for Verizon, version 2.23CDMA Overview Code Division Multiple Access (CDMA) provides a digital cellu

Pagina 95

74 Raven CDMA User Guide for Verizon, version 2.23TABLE 8. Direct CommunicationCommand Parameters Details D[method][d.d.d.d][/ppppp]or D[method][@na

Pagina 96 - Other Settings

Raven CDMA User Guide for Verizon, version 2.23 75 S53=[method][d.d.d.d][/ppppp]method = P - UDP T - TCP N - Telnetd.d.d.d = IP address or name pp

Pagina 97 - Example of the MIB trap

76 Raven CDMA User Guide for Verizon, version 2.23Time/DateTime and Date in the Raven is set to UTC (Coordinated Universal Time). Time is expressed in

Pagina 98

Raven CDMA User Guide for Verizon, version 2.23 77Friends ModeFriends Mode can limit access to the Raven from the Carrier network and the Inter-net.

Pagina 99

78 Raven CDMA User Guide for Verizon, version 2.23KeepaliveKeepalive (page 21) allows the Raven to stay connected to the cellular network even when th

Pagina 100

Raven CDMA User Guide for Verizon, version 2.23 79IP ManagerIP Manager (page 15) is a service from AirLink which allows a Raven with a dynamic IP to b

Pagina 101

80 Raven CDMA User Guide for Verizon, version 2.23*IPMGRKEYn=[key] n= 1 or 2key = 128-bit key in hexadeci-mal [32 hex characters] Sets the 128-bit ke

Pagina 102

Raven CDMA User Guide for Verizon, version 2.23 81

Pagina 103

82 Raven CDMA User Guide for Verizon, version 2.23Logging The Raven allows several different levels of logging. ModbusModbus, commonly used with tele

Pagina 104

Raven CDMA User Guide for Verizon, version 2.23 83TABLE 16. Modbus Settings Command Parameters Details IPL=n n=0 or 1 IP List Dial This allows acces

Pagina 105

Raven CDMA User Guide for Verizon, version 2.23 3Introduction to Raven CDMAUsing CDMA to Communicate with Your Equipment There are two types of addres

Pagina 106 - Troubleshooting

84 Raven CDMA User Guide for Verizon, version 2.23MVMSK=hh hh=hex value 00 - no mask, all 8 bits (default) 0F - only the low order 4 bits Modbus Varia

Pagina 107

Raven CDMA User Guide for Verizon, version 2.23 85SNMP (Simple Network Management Protocol)Simple Network Management Protocol (SNMP) can be used to mo

Pagina 108

86 Raven CDMA User Guide for Verizon, version 2.23SMTP/SMSSMTP (Simple Mail Transfer Protocol) is the de facto standard for email transmis-sion across

Pagina 109

Raven CDMA User Guide for Verizon, version 2.23 87Caution: Your account with Verizon may not support message sending. For most SMS commands (those no

Pagina 110

88 Raven CDMA User Guide for Verizon, version 2.23*SMTPUSER=[user]Maxi-mum: 40 characters user= username The email account username to authenticate w

Pagina 111 - What is the COM1000?

Raven CDMA User Guide for Verizon, version 2.23 89Other !DSMS =index[,message]C3210 index= index list (0, 1, 2) message=mes-sage number Deletes one or

Pagina 112

90 Raven CDMA User Guide for Verizon, version 2.23TABLE 19. Other Settings Command Parameters Details *NUMTOIP=n n=0 or 1 Convert 12 digit number to

Pagina 113

Raven CDMA User Guide for Verizon, version 2.23 91APPENDIX 4 Example of the MIB trap AIRLINK-MIB DEFINITIONS ::= BEGINIMPORTSObjectNameFROM SNMPv2-SMI

Pagina 114

92 Raven CDMA User Guide for Verizon, version 2.23status OBJECT IDENTIFIER ::= { airlink 3 }gps OBJECT IDENTIFIER ::= { airlink 4 }-- GENERAL --phoneN

Pagina 115 - Contacting Technical Support

Raven CDMA User Guide for Verizon, version 2.23 93aleosSWVer OBJECT-TYPESYNTAX DisplayStringMAX-ACCESS read-onlySTATUS current ::= { general 5 }a

Comentarios a estos manuales

Sin comentarios